Inspection Notice 3M™ DBI-SALA® ExoFit NEX™ Harnesses - 3M fall Protection

29 / Apr / 2019

3M Fall Protection has learned of the possibility of a manufacturing defect in a dorsal d-ring of ExoFit NEX™ harnesses manufactured between January 2016 and December 2018.

Serious near miss - potential fall from ceiling space - SUEZ Australia

17 / Apr / 2019

On 20/03/2019 a young worker and tradesman were installing conditioning ductwork in the ceiling void. The young worker stood on a non-load bearing piece of wood that broke resulting in his foot penetrating the gyprock while he was moving between joists. Work was immediately stopped and the welfare of the both workers was checked. There were no injuries.

Guideline: Parking vehicles on inclines - WLL

03 / Apr / 2019

During routine works by a contractor on a wellington carriageway, a vehicle within a worksite self-mobilized and veered out of control that resulted in a team member losing their life. While the cause has not been confirmed, if the contractor had use a multi-barrier approach it would have gone a long way to prevent the incident.

Avoid Brake Park Failures - NZTA

25 / Mar / 2019

The Nissan Diesel Owner’s Manual recommends that the park brake hand control valve is overhauled at 12-month intervals. It also recommends that the valve’s operation is thoroughly checked by a qualified diesel technician when the vehicle is being serviced or if there is concern about its operation.

Triple Fatality – workers hit by third party vehicle - Fletcher Building

25 / Mar / 2019

At approximately 1:50 pm on Tuesday, our Higgins team in the Rotorua area suffered a devastating tragedy, losing three friends and colleagues when their work area was struck by a third-party truck while completing regular, programmed road maintenance activities along State Highway 2 near Whakatane where the maximum speed limit is 100 km/hr.